Fabric OS Message Reference 25-43
Publication Number: 53-1000242-01
FW-1275
25
FW-1275
Message
Probable
Cause
Indicates that the number of frame types or commands that the port receives has changed from a value
outside of the acceptable range to a value within the acceptable range. The port has received SCSI Read,
SCSI Write, SCSI Read and Write, SCSI Traffic, or IP commands in a frame.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the end-user
installation.
Severity INFO
FW-1296
Message
Probable
Cause
Indicates that the number of telnet violations has changed. Telnet violations indicate that a telnet
connection request has been received from an unauthorized IP address. The TELNET_POLICY
contains a list of TCP/IP addresses that are authorized to establish telnet connections to switches in the
fabric. The IP addresses use standard "dot" notation (for example, 255.255.255.255).
Recommended
Action
Run the errShow command to determine the IP address that sent the request. Responses to security-
class messages depend on user policies. Consult your security administrator for response strategies and
policies.
Severity INFO
FW-1297
Message
Probable
Cause
Indicates that the number of telnet violations has fallen below the low boundary. Telnet violations
indicate that a telnet connection request has been received from an unauthorized IP address. The
TELNET_POLICY contains a list of TCP/IP addresses that are authorized to establish telnet
connections to switches in the fabric. The IP addresses use standard "dot" notation (for example,
255.255.255.255).
<timestamp>, [FW-1275], <sequence-number>,, INFO, <system-name>,
<Label>, is between high and low boundaries(High=<High value>,
Low=<Low value>). Current value is <Value> <Unit>.
<timestamp>, [FW-1296], <sequence-number>,, INFO, <system-name>,
<Label>, value has changed(High=<High value>, Low=<Low value>).
Current value is <Value> <Unit>.
<timestamp>, [FW-1297], <sequence-number>,, INFO, <system-name>,
<Label>, is below low boundary(High=<High value>, Low=<Low value>).
Current value is <Value> <Unit>.