Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

Fabric OS Message Reference 25-71
Publication Number: 53-1000242-01
FW-1368
25
Severity INFO
FW-1368
Message
Probable
Cause
Indicates that the number of no-FCS violations has changed. This counter records how often the switch
loses contact with the primary FCS switch. When the primary FCS switch in the fabric sends its
certificate to a switch, the receiving switch saves the WWN of that primary FCS switch. If a secure
switch finds that there are no FCSs in the fabric, but it still has the WWN of the last primary FCS
switch, it increments this counter and resets the WWN of the primary FCS to all zeroes.
Recommended
Action
Responses to security-class messages depend on user policies. Consult your security administrator for
response strategies and policies.
Severity INFO
FW-1369
Message
Probable
Cause
Indicates that the number of no-FCS violations has fallen below the low boundary. This counter records
how often the switch loses contact with the primary FCS switch. When the primary FCS switch in the
fabric sends its certificate to a switch, the receiving switch saves the WWN of that primary FCS switch.
If a secure switch finds that there are no FCSs in the fabric, but it still has the WWN of the last primary
FCS switch, it increments this counter and resets the WWN of the primary FCS to all zeroes.
Recommended
Action
No action is required.
Severity INFO
FW-1370
Message
<timestamp>, [FW-1368], <sequence-number>,, INFO, <system-name>,
<Label>, value has changed(High=<High value>, Low=<Low value>).
Current value is <Value> <Unit>.
<timestamp>, [FW-1369], <sequence-number>,, INFO, <system-name>,
<Label>, is below low boundary(High=<High value>, Low=<Low value>).
Current value is <Value> <Unit>.
<timestamp>, [FW-1370], <sequence-number>,, WARNING, <system-name>,
<Label>, is above high boundary(High=<High value>, Low=<Low
value>). Current value is <Value> <Unit>.