Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

28-2 Fabric OS Message Reference
Publication Number: 53-1000242-01
HIL-1103
28
HIL-1103
Message
Probable
Cause
Indicates that the fan voltage is above threshold.
Recommended
Action
Run the psShow command to verify the power supply status.
Try to reseat the faulty fan FRU and power supply FRU to verify that they are seated properly.
If the problem persists, replace the fan FRU or the power supply FRU as necessary.
Severity ERROR
HIL-1104
Message
Probable
Cause
Indicates that the fan voltage is below the threshold.
Recommended
Action
Run the psShow command to verify the power supply status.
Try to reseat the faulty fan FRU and power supply FRU to verify that they are seated properly.
If the problem persists, replace the fan FRU or the power supply FRU as necessary.
Severity ERROR
HIL-1105
Message
Probable
Cause
Indicates that the switch voltage is above threshold. This message is specific to nonbladed switches and
is not applicable to the SilkWorm 12000, 24000, or 48000.
Recommended
Action
For the SilkWorm 200E, 3250 and 3850, the entire switch must be replaced, because these switches do
not have FRUs.
<timestamp>, [HIL-1103], <sequence-number>,, ERROR, <system-name>,
Blower <blower number> faulted, <nominal voltage> (<measured
voltage>) is above threshold.
<timestamp>, [HIL-1104], <sequence-number>,, ERROR, <system-name>,
Blower <blower number> faulted, <nominal voltage> (<measured
voltage>) is below threshold.
<timestamp>, [HIL-1105], <sequence-number>,, ERROR, <system-name>,
Switch error, <nominal voltage> (<measured voltage>) above
threshold.