Message
Probable
Cause
Indicates that the fan is not faulty.
Recommended
Action
This can only occur on switches with non-removable fans. It follows a previous indication of faultiness.
If the fan continues to generate this message, it indicates oscillation between faulty and non-faulty
behavior. Replace the switch because the fan is not field-replaceable.
Severity INFO
HIL-1301
Message
Probable
Cause
Indicates that a fan FRU has failed or has been removed. This message is often preceded by a low speed
error message. This problem can cause the switch to overheat.
Recommended
Action
Replace the affected fan FRU immediately.
Severity WAR NIN G
HIL-1302
Message
Probable
Cause
Indicates that multiple fan FRUs have failed or are missing on a switch. This message is often preceded
by a low fan speed message.
Recommended
Action
Replace the affected fan FRUs immediately.
Severity WAR NIN G
<timestamp>, [HIL-1208], <sequence-number>,, INFO, <system-name>,
Fan <fan number> is not faulty.
<timestamp>, [HIL-1301], <sequence-number>,, WARNING, <system-
name>, 1 blower failed or missing. Replace failed or missing blower
assembly immediately.
<timestamp>, [HIL-1302], <sequence-number>,, WARNING, <system-
name>, <count> blowers failed or missing. Replace failed or missing
blower assemblies immediately.