MS System Messages
MS-1001
Message
Probable
Cause
Indicates that the management server (MS) has segmented from another switch domain at the specified
port number due to errors or inconsistencies defined in the MS platform service.
Recommended
Action
Reboot or power cycle the switch.
Severity WAR NIN G
MS-1002
Message
Probable
Cause
The MS platform service is unstable.
The message string can be one of the following:
<No Resp for GCAP from>
The switch did not respond to a request for GCAP (MS Get Capabilities) command.
Recommended Action: No action is required.
<GCAP sup but not PL by>
The GCAP (MS Get Capabilities) is supported but the flag for MS platform service is not set.
Recommended Action: Set the flag for the MS Platform Service.
<GCAP Rejected (reason =BUSY) by>
The GCAP (MS Get Capabilities) is not supported by another switch.
Recommended Action: Upgrade the firmware level on the switch to a level that supports RCS.
<Reject EXGPLDB from>
The request to the exchange platform database was rejected. The remote switch might be busy.
Recommended Action: Wait a few minutes and try the command again.
The domain number is the target domain that caused error.
<timestamp>, [MS-1001], <sequence-number>,, WARNING, <system-name>,
MS Platform Segmented port=<port number>(<reason for segmentation>
<domain>)
<timestamp>, [MS-1002], <sequence-number>,, INFO, <system-name>, MS
Platform Service Unstable(<message string><domain number>)