Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

Fabric OS Message Reference 44-3
Publication Number: 53-1000242-01
MS-1005
44
Recommended
Action
This message is often transitory.
The fabric might be reconfiguring, forming, or merging. Wait a few minutes and try the operation again.
Run the fabricShow command or the secFabricShow command to verify that the number of domains
matches the Management Server known domains.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity INFO
MS-1005
Message
Probable
Cause
Indicates that MS received an invalid common transport (CT) response from switch domain. MS
expects either a CT accept IU or a reject IU; MS received neither response, which violates the Fibre
Channel Generic Services (FS-GS) specification.
Recommended
Action
Check the integrity of the FC switch at the specified domain. It is not sending correct MS information as
defined by the FC-FS standard.
Severity ERROR
MS-1006
Message
Probable
Cause
Indicates that MS received IU data of unexpected size. The IU payload and the IU size might be
inconsistent with each other or with the command that is currently being processed.
Recommended
Action
Wait a few minutes and try the operation again.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity ERROR
MS-1008
Message
<timestamp>, [MS-1005], <sequence-number>,, ERROR, <system-name>,
MS Invalid CT Response from d=<domain>
<timestamp>, [MS-1006], <sequence-number>,, ERROR, <system-name>,
MS Unexpected iu_data_sz=<number of bytes>
<timestamp>, [MS-1008], <sequence-number>,, ERROR, <system-name>,
MS Failure while initializing <action>