Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

58-26 Fabric OS Message Reference
Publication Number: 53-1000242-01
SEC-1098
58
SEC-1098
Message
Probable
Cause
Indicates that the specified policy could not be found.
Recommended
Action
Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command
and contact your switch service provider.
Severity ERROR
SEC-1099
Message
Probable
Cause
Indicates that there has been a corruption during the distribution of the security database. This can only
occur when the primary FCS is distributing the security database to the other switches in the fabric and
local validation finds that there is an error in the security database. This is a rare occurrence.
Recommended
Action
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be
in the ready state. If a switch is in the error state, the database might not be correctly updated for that
specific switch.
Severity ERROR
SEC-1100
Message
Probable
Cause
Indicates that there has been a corruption during the distribution of the security database. This can only
occur when the primary FCS is distributing the security database to the other switches in the fabric and
local validation finds that there is an error in the security database. This is a rare occurrence.
Recommended
Action
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be
in the ready state. If a switch is in the error state, the database might not be correctly updated for that
specific switch.
Severity ERROR
<timestamp>, [SEC-1098], <sequence-number>,, ERROR, <system-name>,
No <active or defined> FCS list.
<timestamp>, [SEC-1099], <sequence-number>,, ERROR, <system-name>,
Please enable your switch before running secModeEnable.
<timestamp>, [SEC-1100], <sequence-number>,, ERROR, <system-name>,
FCS switch present. Command terminated.