Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

65-4 Fabric OS Message Reference
Publication Number: 53-1000242-01
TRCE-1009
65
Severity CRITICAL
TRCE-1009
Message
Probable
Cause
Indicates that the standby CP is unable to communicate trace information to active CP. This message is
only applicable to the SilkWorm 12000, 24000, and 48000.
Recommended
Action
Run the haShow command to verify that the current CP is standby and the active CP is active.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity ERROR
TRCE-1010
Message
Probable
Cause
Indicates that the trace daemon (traced), used for transferring trace files, failed to start. The trace
capability within the switch is unaffected.
Recommended
Action
Reboot the CP (dual-CP system) or restart the switch.
Run traceFtp to set up for automatic FTP transfers.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity ERROR
TRCE-1011
Message
Probable
Cause
Indicates that a manual transfer of trace dump files has occurred.
<timestamp>, [TRCE-1009], <sequence-number>,, ERROR, <system-name>,
Unable to alert active CP that a dump has occurred.
<timestamp>, [TRCE-1010], <sequence-number>,, ERROR, <system-name>,
Traced fails to start
<timestamp>, [TRCE-1011], <sequence-number>,, INFO, <system-name>,
Trace dump manually transferred to target ' <optional string to
indicate which slot the dump is ftped out.> ': <result>.