Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

67-2 Fabric OS Message Reference
Publication Number: 53-1000242-01
TS-1006
67
Recommended
Action
Run the tsClockServer command to verify that the principal or primary FCS switch has the clock
server IP configured correctly. Verify that this clock server is accessible to the switch and functional. If
the principal or primary FCS does not support the feature, either choose a different switch for the role or
reset the clock server to LOCL.
Severity WAR NIN G
TS-1006
Message
Probable
Cause
Indicates that a time service event is occurring or has failed. The message might be one of the
following:
Init failed. Time Service exiting
Probable Cause: Initialization error, Time Server exits.
Synchronizing time of day clock
Probable Cause: Usually logged during temporary operational issues when the clock goes out of
synchronization: For example, when a time update packet is missed due to fabric reconfiguration or
role change of the principal or primary FCS switch. If the message does not recur, it should be
ignored.
Validating time update
Probable Cause: Usually logged during temporary operational issues when a time update packet
cannot be validated in a secure fabric. For example, during fabric reconfiguration or role change of
the primary FCS switch. If the message does not recur, it should be ignored.
Recommended
Action
No action is required.
Severity INFO
<timestamp>, [TS-1006], <sequence-number>,, INFO, <system-name>,
<message>