Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

Fabric OS Message Reference 73-3
Publication Number: 53-1000242-01
ZONE-1006
73
ZONE-1006
Message
Probable
Cause
Indicates that one or more devices are zoned as WWN devices and also zoned as <domain, portarea>
devices. The device(s) are used to specify zone members over separate zones.
Recommended
Action
If hardware zoning enforcement is preferred, edit the zoning database to have the device zoned using
only one specification type, either WWN or <domain, portarea>.
Severity WAR NIN G
ZONE-1007
Message
Probable
Cause
Indicates that frame filter logic reported a failure during one of the IOCTL calls. The IOCTL call from
which the failure is reported is listed as part of the error message. This is usually a programming error
when adding CAM entries before the filter setup.
Recommended
Action
There are two ways to avoid this problem.
Avoid having too many hosts zoned with a set of target devices at a single port.
Avoid having too many zones directed at a single port group on the switch.
Severity INFO
ZONE-1008
Message
Probable
Cause
Indicates that the total number of entries of S_ID CAM is above the limit while creating or adding a
zone group. The maximum number of CAM entries allowed depends on the ASIC.
Recommended
Action
If hardware zoning enforcement is preferred, edit the zoning database to have zoned PIDs for that port.
Severity WAR NIN G
<timestamp>, [ZONE-1006], <sequence-number>,, WARNING, <system-
name>, WARNING - WWN(<WWN number>) in HARD PORT zone <zone_name>.
<timestamp>, [ZONE-1007], <sequence-number>,, INFO, <system-name>,
Ioctl(<function>) in (<error message>) at port (<port number>)
returns code (<error string>) and reason string (<reason string>)
<timestamp>, [ZONE-1008], <sequence-number>,, WARNING, <system-
name>, WARNING - port <port number> Out of CAM entries