Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

79-12 Fabric OS Message Reference
Publication Number: 53-1000242-01
SULB-1026
79
Recommended
Action
Since the operation may have been started to repair the secondary partition, run the firmwareShow
command to verify the versions. If the blade firmware version is still inconsistent with the active CP
firmware, firmwareDownload will be started automatically to the blade again. If the blade firmware is
the same as the active CP firmware, firmwareDownload has completed successfully on the blade.
Severity WAR NIN G
SULB-1026
Message
Probable
Cause
firmwareCommit has started on the indicated blade. The operation may be a normal part of
firmwareDownload. It can also be started to repair the secondary partition of the blade if the secondary
partition is corrupted.
Recommended
Action
No action is required.
Severity WAR NIN G
SULB-1030
Message
Probable
Cause
The error can be caused by unexpected disruption of firmwareDownload command, for exampling
powering the switch off and on in the middle of a firmwareDownload. This error can also be caused by
persistent storage hardware failure, or a software error.
Recommended
Action
firmwareDownload process will continue after the switch is rebooted. So continue to run the
firmwareDownloadStatus command to monitor the progress. However, if this problem persists,
contact the service provider for further actions.
Severity WAR NIN G
SULB-1034
Message
AUDIT, <timestamp>, [SULB-1026], WARNING, FIRMWARE, <event-
initiator-details>, <event-location>, , Firmware commit operation
started on the blade in slot <Slot number>.
AUDIT, <timestamp>, [SULB-1030], WARNING, FIRMWARE, <event-
initiator-details>, <event-location>, , The switch has rebooted
during relocating the internal firmware image.
AUDIT, <timestamp>, [SULB-1034], ERROR, FIRMWARE, <event-initiator-
details>, <event-location>, , Firmwaredownload timed out.