Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

36 Fabric OS Message Reference
53-1002448-01
AG-1004
2
Recommended
Action
Configure two or more N_Ports to connect to the same fabric; then execute the ag --failoverenable
command to enable failover on these N_Ports.
Severity WARNING
AG-1004
Message <timestamp>, [AG-1004], <sequence-number>,, ERROR, <system-name>, Invalid
response to fabric login (FLOGI) request from the fabric for N_Port <port>.
Probable Cause Indicates the fabric sent an invalid response to the FLOGI Extended Link Service (ELS) for the
specified N_Port.
Recommended
Action
Check the configuration of the fabric switch.
If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.
Severity ERROR
AG-1005
Message <timestamp>, [AG-1005], <sequence-number>,, WARNING, <system-name>, FDISC
response was dropped because F_Port <port> is offline.
Probable Cause Indicates the F_Port connected to the host is offline, which caused the Fabric Discovery (FDISC)
response to drop.
Recommended
Action
Check the configuration of the host connected to the specified F_Port.
Severity WARNING
AG-1006
Message <timestamp>, [AG-1006], <sequence-number>,, INFO, <system-name>, Access Gateway
mode has been <msg>.
Probable Cause Indicates that the Access Gateway mode has been enabled or disabled.
Recommended
Action
Execute the ag
--modeshow command to verify the current status of the Access Gateway mode.
Severity INFO