Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

46 Fabric OS Message Reference
53-1002448-01
AG-1039
2
AG-1039
Message <timestamp>, [AG-1039], <sequence-number>,, INFO, <system-name>, F_Port <Port
that was reset> was reset because a WWN mapped device using it, through N_Port
<Port who's state change caused the reset>, went offline.
Probable Cause Indicates that a port needed to be reset because an N_Port went offline and the changes need to
be propagated to all involved devices.
Recommended
Action
No action is required. This port reset was not an error.
Severity INFO
AG-1040
Message <timestamp>, [AG-1040], <sequence-number>,, WARNING, <system-name>, PID of the
devices connected to Port <port> may have changed, as the port was toggled. Check
EE monitor’s configuration as it might not be functional.
Probable Cause Indicates that N_Port ID virtualization (NPIV) assigns a new PID each time the same port is
disabled and then re-enabled. As the PID has changed, the end-to-end (EE) monitors installed with
the previous PID stops functioning.
Recommended
Action
Install new EE monitors with the new PID of the port to be monitored.
Severity WARNING
AG-1041
Message <timestamp>, [AG-1041], <sequence-number>,, WARNING, <system-name>, Static
F_Ports mapped to N_Port <port> are disabled as Trunking is enabled on the N_Port.
Probable Cause Indicates that the trunk is enbled on the static N_Port.
Recommended
Action
Delete static mapping on the Access Gateway using the ag --staticdel N_Port F_Port[s] command or
disable the trunk on N_Port.
Severity WARNING