Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 47
53-1002448-01
Chapter
3
AN System Messages
AN-1001
Message <timestamp>, [AN-1001], <sequence-number>,, ERROR, <system-name>, Failed to
allocate memory: <function name>
Probable Cause Indicates that the specified function has failed to allocate memory.
Recommended
Action
Check memory usage on the switch using the memShow command. Restart or power cycle the
switch.
Severity ERROR
AN-1002
Message <timestamp>, [AN-1002], <sequence-number>,, ERROR, <system-name>, Failed to
initialize; rc = <error>.
Probable Cause Indicates that the initialization of the trafd daemon has failed.
Recommended
Action
Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS
Command Reference Manual for more information on this command.
Severity ERROR
AN-1003
Message <timestamp>, [AN-1003], <sequence-number>,, WARNING, <system-name>, Latency
bottleneck on port <slot number>/<port number within slot number>. <percentage of
seconds affected by latency bottlenecking> pct. of <observation period over which
the percentage of affected seconds is reported> secs. affected. Avg. time b/w
transmits <observed average time between frames during affected seconds> us. Avg.
slowdown <observed throughput drop factor during affected seconds>.
Probable Cause For an F_Port, it indicates that the attached device is slow in responding to frames going out of this
port. This latency may be inherent in the device or due to heavy workload on the device. For an
E_Port, it indicates a downstream primary bottleneck.
Recommended
Action
If the port is an F_Port, examine the connected device for the source of the latency. If the port is a
long-distance E_Port, ensure that there are enough buffer credits to service the link distance.
Severity WARNING