Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

48 Fabric OS Message Reference
53-1002448-01
AN-1004
3
AN-1004
Message <timestamp>, [AN-1004], <sequence-number>,, WARNING, <system-name>, Congestion
bottleneck on port <slot number>/<port number within slot number>. <percentage of
seconds affected by congestion bottlenecking> pct. of <observation period over
which the percentage of affected seconds is reported> secs. affected.
Probable Cause Indicates that the volume of outgoing traffic at this port is too high for the capacity of the link.
Recommended
Action
Add more capacity on the path, using trunk links if possible.
Severity WARNING
AN-1005
Message <timestamp>, [AN-1005], <sequence-number>,, INFO, <system-name>, Slot <slot
number>, port <port number within slot number> has <bottleneck type> bottleneck
cleared.
Probable Cause Indicates that the bottleneck was cleared on the port.
Recommended
Action
No action is required.
Severity INFO
AN-1010
Message <timestamp>, [AN-1010], <sequence-number>,, WARNING, <system-name>, Severe
latency bottleneck detected at Slot <slot number> port <port number within slot
number>.
Probable Cause Indicates credit loss at the specified port, a downstream port, or a very high latency device at the
edge of the fabric.
Recommended
Action
Contact your vendor's customer support for assistance.
Severity WARNING
AN-1011
Message <timestamp>, [AN-1011], <sequence-number>,, WARNING, <system-name>, Could not
distinguish between primary and dependent severe latency bottleneck on slot <slot
number> port <port number within slot number> because port mirroring is enabled on
this port.
Probable Cause Indicates that resources needed to determine whether there is complete credit loss on a VC at this
port are in use by port mirroring.