Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 51
53-1002448-01
Chapter
4
ANV System Messages
ANV-1001
Message <timestamp>, [ANV-1001], <sequence-number>,, ERROR, <switch-name>, Port <port
number> port fault. Change the SFP or check the cable.
Probable Cause Indicates a deteriorated small form-factor pluggable (SFP), an incompatible SFP pair, or a faulty
cable between the peer ports.
Recommended
Action
Verify that compatible SFPs are used on the peer ports, the SFPs have not deteriorated, and the
fibre channel cable is not faulty. Replace the SFPs or the cable, if necessary.
Severity ERROR
ANV-1002
Message <timestamp>, [ANV-1002], <sequence-number>, FFDC, ERROR, <switch-name>, Port
<port number> chip faulted due to an internal error.
Probable Cause Indicates an internal error. All the ports on the chip will be disrupted.
Recommended
Action
To recover a bladed system, execute the slotPowerOff and slotPowerOn commands on the blade. To
recover a non-bladed system, execute the fastBoot command on the switch.
Severity ERROR
ANV-1003
Message <timestamp>, [ANV-1003], <sequence-number>,, CRITICAL, <switch-name>, S<slot
number>,C<chip index>: HW ASIC Chip error. Type = 0x<chip error type>, Error =
<chip error string>.
Probable Cause Indicates an internal error in the application-specific integrated circuit (ASIC) hardware that may
degrade the data traffic.
Recommended
Action
Restart the system at the next maintenance window. If the problem persists, replace the faulted
blade.
Severity CRITICAL