Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 63
53-1002448-01
AUTH-1030
5
AUTH-1030
Message <timestamp>, [AUTH-1030], <sequence-number>,, ERROR, <system-name>, Invalid
message code for <message phase> message: port <port number>.
Probable Cause Indicates the receiving payload does not have valid message code for a particular authentication
phase.
Recommended
Action
Usually this problem is transient. The authentication might fail.
Reinitialize authentication using the portDisable and portEnable commands or the switchDisable
and switchEnable commands.
If the message persists, run the supportFtp command (as needed) to set up automatic FTP
transfers; then run the supportSave command and contact your switch service provider.
Severity ERROR
AUTH-1031
Message <timestamp>, [AUTH-1031], <sequence-number>,, ERROR, <system-name>, Failed to
retrieve secret value: port <port number>.
Probable Cause Indicates that the secret value was not set properly for the authenticated entity.
Recommended
Action
Reset the secret value by using the secAuthSecret command.
Reinitialize authentication using the portDisable and portEnable commands or the switchDisable
and switchEnable commands.
Severity ERROR
AUTH-1032
Message <timestamp>, [AUTH-1032], <sequence-number>,, ERROR, <system-name>, Failed to
generate <data type> for <message payload> payload: length <data length>, error
code <error code>, port <port number>.
Probable Cause Indicates that the authentication process failed to generate specific data (that is, challenge, nonce,
or response data) for an authentication payload. This usually relates to internal failure.
A nonce is a single-use, usually random value used in authentication protocols to prevent replay
attacks.
Recommended
Action
Usually this problem is transient. The authentication might fail.
Reinitialize authentication using the portDisable and portEnable commands or the switchDisable
and switchEnable commands.
If the message persists, run the supportFtp command (as needed) to set up automatic FTP
transfers; then run the supportSave command and contact your switch service provider.
Severity ERROR