Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 71
53-1002448-01
Chapter
7
BL System Messages
BL-1000
Message <timestamp>, [BL-1000], <sequence-number>,, INFO, <system-name>, Initializing
ports...
Probable Cause Indicates that the switch has started initializing the ports.
Recommended
Action
No action is required.
Severity INFO
BL-1001
Message <timestamp>, [BL-1001], <sequence-number>,, INFO, <system-name>, Port
initialization completed.
Probable Cause Indicates that the switch has completed initializing the ports.
Recommended
Action
No action is required.
Severity INFO
BL-1002
Message <timestamp>, [BL-1002], <sequence-number>, FFDC, CRITICAL, <system-name>, Init
Failed: slot <slot number> DISABLED because internal ports were not ONLINE, <list
of internal port number not ONLINE>.
Probable Cause Indicates that the blade initiation failed because one or more of the internal ports were not online.
The blade is faulted.
Recommended
Action
Make sure that the blade is seated correctly. If the blade is seated correctly, restart or power cycle
the blade.
Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Additional blade
fault messages precede and follow this error, providing more information. See other error
messages for recommended action.
If the message persists, replace the blade.
Severity CRITICAL