Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

72 Fabric OS Message Reference
53-1002448-01
BL-1003
7
BL-1003
Message <timestamp>, [BL-1003], <sequence-number>, FFDC, CRITICAL, <system-name>,
Faulting blade in slot <slot number>
.
Probable Cause Indicates a faulty blade in the specified slot number.
Recommended
Action
Make sure that the blade is seated correctly. If the blade is seated correctly, restart or power cycle
the blade.
Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric
OS Command Reference for more information on these commands.
If the message persists, replace the blade.
Severity CRITICAL
BL-1004
Message <timestamp>, [BL-1004], <sequence-number>, FFDC, CRITICAL, <system-name>,
Suppressing blade fault in slot <slot number>
.
Probable Cause Indicates that the specified blade experienced a failure but was not faulted due to a user setting.
Recommended
Action
Restart or power cycle the blade, using the slotPowerOff and slotPowerOn commands.
Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric
OS Command Reference for more information on these commands.
If the message persists, replace the blade.
Severity CRITICAL
BL-1006
Message <timestamp>, [BL-1006], <sequence-number>,, INFO, <system-name>, Blade <slot
number> NOT faulted. Peer blade <slot number> experienced abrupt failure.
Probable Cause Indicates that the errors (mostly synchronization errors) on this blade are harmless. Probably, the
standby control processor (CP) blade connected to the active CP blade has experienced transitory
problems.
Recommended
Action
Use the haShow command to verify that the standby CP is healthy. If problem persists remove and
reinstall the faulty blade.
Severity INFO