Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 75
53-1002448-01
BL-1013
7
If the message persists, replace the blade or the (nonbladed) switch.
Severity ERROR
BL-1013
Message <timestamp>, [BL-1013], <sequence-number>,, ERROR, <system-name>, bport <port
number> port is faulted. status=0x<interrupt status> Port <port number> will be
re-enabled in 1 minute.
Probable Cause Indicates that the port generated an excessive number of interrupts that might prove fatal to the
switch operation. The port is disabled to prevent the control processor (CP) from becoming too
busy. The bport is the blade port; this number might not correspond to a user port number.
Recommended
Action
Make sure to capture the console output during this process.
Check for a faulty cable, small form-factor pluggable (SFP), or device attached to the specified port.
On a bladed switch, run the slotPowerOff and slotPowerOn commands.
On a nonbladed switch, restart or power cycle the switch.
If the message persists, replace the blade.
Severity ERROR
BL-1014
Message <timestamp>, [BL-1014], <sequence-number>,, ERROR, <system-name>, bport <port
number> port int. is disabled. status=0x<interrupt status>.
Probable Cause Indicates that the port generated an excessive number of interrupts that might prove fatal to the
switch operation. The port is disabled to prevent the control processor (CP) from becoming too
busy. The bport is the blade port; this number might not correspond to a user port number.
Recommended
Action
Make sure to capture the console output during this process.
On a bladed switch, run the slotPowerOff and slotPowerOn commands.
On a nonbladed switch, reboot the switch.
Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled.
If there is a hardware error, if the slotPowerOff or slotPowerOn fails on the bladed switch or if errors
are encountered again:
On the Brocade 24000, and 48000, replace the blade field-replaceable unit (FRU).
On the Brocade 3900, replace the motherboard FRU.
On the Brocade 200E, 3016, 3250, 3850, or 4100, 4012, 4016, 4018, 4024, 4900, 7500,
AP7600, and 5000, replace the switch.
Severity ERROR