Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

76 Fabric OS Message Reference
53-1002448-01
BL-1015
7
BL-1015
Message <timestamp>, [BL-1015], <sequence-number>,, ERROR, <system-name>, bport <port
number> port is faulted. status=0x<interrupt status>.
Probable Cause Indicates that the port generated an excessive number of interrupts that might prove fatal to the
switch operation. The port is disabled to prevent the CP from becoming too busy. The bport is the
blade port; this number might not correspond to a user port number.
Recommended
Action
Make sure to capture the console output during this process.
On a bladed switch, run the slotPowerOff and slotPowerOn commands.
On a nonbladed switch, reboot the switch.
Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled.
If there is a hardware error, if the slotPowerOff or slotPowerOn fails on the bladed switch or if errors
are encountered again:
On the Brocade 24000, and 48000, replace the blade field-replaceable unit (FRU).
On the Brocade 3900, replace the motherboard FRU.
On the Brocade 200E, 3016, 3250, 3850, or 4100, 4012, 4016, 4018, 4024, 4900, 7500,
AP7600, and 5000, replace the switch.
Severity ERROR
BL-1016
Message <timestamp>, [BL-1016], <sequence-number>, FFDC, CRITICAL, <system-name>, Blade
port <port number> in slot <slot number> failed to enable.
Probable Cause Indicates that the specified blade port has failed to get enabled.
Recommended
Action
Make sure that the blade is seated correctly.
If the blade is seated correctly, restart or power cycle the blade.
Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric
OS Command Reference for more information on these commands.
If the message persists, replace the blade.
Severity CRITICAL
BL-1017
Message <timestamp>, [BL-1017], <sequence-number>,, INFO, <system-name>, Slot <slot
number>
Initializing...
Probable Cause Indicates that the slot has started initializing the ports.