Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 77
53-1002448-01
BL-1018
7
Recommended
Action
No action is required.
Severity INFO
BL-1018
Message <timestamp>, [BL-1018], <sequence-number>,, INFO, <system-name>, Slot <slot
number>
Initialization completed.
Probable Cause Indicates that the slot has completed initializing the ports.
Recommended
Action
No action is required.
Severity INFO
BL-1019
Message <timestamp>, [BL-1019], <sequence-number>,, INFO, <system-name>, Slot <Slot
number>, retry <Retry Number>, internal port retry initialization, <List of
internal ports retrying initialization>.
Probable Cause Indicates that the slot had internal ports not online and that the system is retrying to bring the
ports that failed back online.
Recommended
Action
No action is required.
Severity INFO
BL-1020
Message <timestamp>, [BL-1020], <sequence-number>, FFDC, CRITICAL, <system-name>, Switch
timed out initializing the chips.
Probable Cause Indicates that the switch has failed to initialize the application-specific integrated circuit (ASIC)
chips.
Recommended
Action
Restart or power cycle the switch.
Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric
OS Command Reference for more information on these commands.
If the message persists, replace the switch.
Severity CRITICAL