Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 79
53-1002448-01
BL-1024
7
BL-1024
Message <timestamp>, [BL-1024], <sequence-number>,, INFO, <system-name>, All ports on the
blade in slot
<slot number> will be reset as part of the firmware upgrade.
Probable Cause Indicates that a recent firmware upgrade caused the blade's firmware to be upgraded and resulted
in the cold upgrade. As part of the upgrade, all datapath elements were reset.
Recommended
Action
No action is required.
Severity INFO
BL-1025
Message <timestamp>, [BL-1025], <sequence-number>,, INFO, <system-name>, All GigE/FCIP
Virtualization ports on the blade in slot
<slot number> will be reset as part of
the firmware upgrade.
Probable Cause Indicates that a recent firmware upgrade caused the blade's firmware to be upgraded and resulted
in the cold upgrade. As part of the upgrade, all GbE or Fibre Channel over IP (FCIP) or Virtualization
data elements or FC Fastwrite ports were reset.
Recommended
Action
No action is required.
Severity INFO
BL-1026
Message <timestamp>, [BL-1026], <sequence-number>,, CRITICAL, <system-name>, Internal
port offline during warm recovery, state <port state> (0x<port ID>).
Probable Cause Indicates that an internal port went offline during the warm recovery of the switch. The switch will
reboot and start a cold recovery.
Recommended
Action
Collect supportSave information, then restart the switch and run the diagPost command to ensure
Power-On Self-Test (POST) is enabled. If the problem persists, replace the switch.
Severity CRITICAL
BL-1027
Message <timestamp>, [BL-1027], <sequence-number>,, CRITICAL, <system-name>, Blade in
slot <slot number> faulted, boot failed; status 0x<boot status> 0x<1250 0 boot
status> 0x<1250 1 boot status>.
Probable Cause Indicates that the blade failed to boot properly.