Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 95
53-1002448-01
BM-1056
10
BM-1056
Message <timestamp>, [BM-1056], <sequence-number>,, INFO, <system-name>, AP is not
configured. Persistently disabling all ports on the switch.
Probable Cause Indicates the policy of the specified switch is to persistently disable all ports the first time the AP is
detected. This may be caused by one of the following:
The AP was detected for the first time on this switch.
The switch was configured under a different mode.
Recommended
Action
Configure the switch to persistently enable all ports.
Severity INFO
BM-1058
Message <timestamp>, [BM-1058], <sequence-number>,, WARNING, <system-name>, Download of
AP firmware failed for the switch. Reissue firmwaredownload to recover.
Probable Cause Indicates the automatic firmware upgrade on the application processor (AP) has failed, because
the firmware version running on the AP was detected to be different from the system firmware
because of a firmware upgrade.
Recommended
Action
Issue the firmwareDownload command to recover the AP.
Severity WARNING