Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 97
53-1002448-01
Chapter
11
C2 System Messages
C2-1001
Message <timestamp>, [C2-1001], <sequence-number>,, ERROR, <system-name>, Port <port
number> port faulted due to SFP validation failure. Please check if the SFP is
valid for the configuration.
Probable Cause Indicates a deteriorated SFP, an incompatible SFP pair, or a faulty cable between the peer ports.
Recommended
Action
Verify that you are using compatible SFPs on the peer ports. Verify that the SFPs have not
deteriorated and the Fibre Channel cable is not faulty. Replace SFPs or cable if necessary.
Severity ERROR
C2-1002
Message <timestamp>, [C2-1002], <sequence-number>, FFDC, ERROR, <system-name>, Port <port
number> chip faulted due to an internal error.
Probable Cause Indicates an internal error. All the ports on the blade or switch will be disrupted.
Recommended
Action
For a bladed system, execute the slotpoweroff and slotpoweron commands on the blade to recover
the system. For a non-bladed system, execute the fastboot command on the switch to recover the
system.
Severity ERROR
C2-1004
Message <timestamp>, [C2-1004], <sequence-number>,, ERROR, <system-name>, S<slot
number>,C<chip index>: Invalid DMA ch pointer, chan:<Channel number>,
good_addr:0x<Good address> bad_addr:0x<Bad address>.
Probable Cause Indicates an internal error in the Application-Specific Integrated Circuit (ASIC) hardware that may
degrade data traffic.
Recommended
Action
Whenever this error is observed, restart the system at the next maintenance window. If the problem
persists, replace the blade.
Severity ERROR