Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 99
53-1002448-01
C2-1009
11
C2-1009
Message Message <timestamp>, [C2-1009], <sequence-number>,, WARNING, <system-name>,
S<slot number>,P<port number>(<blade port number>): portcfglongdistance
vc_translation_link_init = 1 overwrites fill word IDLE. ARB will be used on the
link.
Probable Cause Indicates portcfglongdistance vc_translation_link_init 1 overwrites fill word IDLE. ARB will be used
on the link.
Recommended
Action
No action is required.
Severity WARNING
C2-1010
Message Message <timestamp>, [C2-1010], <sequence-number>,, CRITICAL, <system-name>,
S<slot number>, C<chip index>: Internal monitoring has identified suspect
hardware, blade may need to be reset or replaced: fault1:<fault1_cnt>,
fault2:<fault2_cnt> th2:0x<threshold_used>.
Probable Cause Indicates above normal errors observed in hardware that may or may not impact data traffic.
Recommended
Action
Whenever this error is observed persistently, power cycle the specified blade. If the problem
persists, replace the blade.
Severity CRITICAL
C2-1012
Message Message <timestamp>, [C2-1012], <sequence-number>,, WARNING, <system-name>,
S<slot number>,P<port number>(<blade port number>): Link Timeout on internal port
ftx=<frame transmitted> tov=<real timeout value> (><expected timeout value>)
vc_no=<vc number> crd(s)lost=<Credit(s) lost> complete_loss:<complete credit
loss>.
Probable Cause Indicates that one or more credits have been lost on a back-end port, and there is no traffic on that
port for two seconds.
Recommended
Action
Turn on the back-end credit recovery to reset the link and recover the lost credits. If credit recovery
has already been turned on, the link will be reset to recover the credits and no action is required.
Severity WARNING