Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 103
53-1002448-01
Chapter
12
C3 System Messages
C3-1001
Message <timestamp>, [C3-1001], <sequence-number>,, ERROR, <system-name>, Port <port
number> failed due to SFP validation failure. Check if the SFP is valid for the
configuration.
Probable Cause Indicates a deteriorated small form-factor pluggable (SFP), an incompatible SFP pair, or a faulty
cable between the peer ports.
Recommended
Action
Verify that compatible SFPs are used on the peer ports, the SFPs have not deteriorated, and the
Fibre Channel cable is not faulty. Replace SFPs or cable if necessary.
Severity ERROR
C3-1002
Message <timestamp>, [C3-1002], <sequence-number>, FFDC, ERROR, <system-name>, Port <port
number> chip failed due to an internal error.
Probable Cause Indicates an internal error. All the ports on the blade or switch will be disrupted.
Recommended
Action
To recover a bladed system, execute the slotPowerOff and slotPowerOn commands on the blade. To
recover a non-bladed system, execute the fastboot command on the switch.
Severity ERROR
C3-1004
Message <timestamp>, [C3-1004], <sequence-number>,, ERROR, <system-name>, S<slot
number>,C<chip index>: Invalid DMA ch pointer, chan:<Channel number>,
good_addr:0x<Good address> bad_addr:0x<Bad address>.
Probable Cause Indicates an internal error in the Application-Specific Integrated Circuit (ASIC) hardware that may
degrade data traffic.
Recommended
Action
Whenever this error is observed, reboot the system at the next maintenance window. If the problem
persists, replace the blade.
Severity ERROR