Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 105
53-1002448-01
C3-1010
12
Recommended
Action
No action is required.
Severity WARNING
C3-1010
Message <timestamp>, [C3-1010], <sequence-number>,, CRITICAL, <system-name>, S<slot
number>,C<chip index>: Above normal hardware errors were observed:
fault1:<fault1_cnt>, fault2:<fault2_cnt> thresh2:0x<threshold_used>.
Probable Cause Indicates above normal errors observed in hardware that may or may not impact data traffic.
Recommended
Action
Whenever this error is observed persistently, power cycle the specified blade. If the problem
persists, replace the blade.
Severity CRITICAL
C3-1011
Message <timestamp>, [C3-1011], <sequence-number>,, INFO, <system-name>, Detected a stuck
VC on internal Port Slot <slot number>, Port <port number>(<blade port number>)
vc_no=<vc number> crd(s)lost=<Credit(s)lost>.
Probable Cause Indicates that a stuck VC was detected on the specified port.
Recommended
Action
Turn on the back-end credit recovery to reset the link and recover the lost credits. If credit recovery
has already been turned on, the link will be reset to recover the credits and no action is required.
Severity INFO
C3-1012
Message <timestamp>, [C3-1012], <sequence-number>,, WARNING, <system-name>, S<slot
number>,P<port number>(<blade port number>): Link Timeout on internal port
ftx=<frame transmitted> tov=<real timeout value> (><expected timeout value>)
vc_no=<vc number> crd(s)lost=<Credit(s) lost> complete_loss:<Compless credit
loss>.
Probable Cause Indicates that one or more credits have been lost on a back-end port, and there is no traffic on that
port for two seconds.
Recommended
Action
Turn on the back-end credit recovery to reset the link and recover the lost credits. If credit recovery
has already been turned on, the link will be reset to recover the credits and no action is required.
Severity WARNING