Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 119
53-1002448-01
CDR-1016
15
Recommended
Action
Whenever this error is observed persistently, power cycle the specified blade. If the problem
persists, replace the blade.
Severity WARNING
CDR-1016
Message <timestamp>, [CDR-1016], <sequence-number>,, ERROR, <system-name>, Port is
faulted due to port re-initialization failure on internal Port S<slot
number>,P<port number>(<blade port number>) with reason <port fault reason>.
Probable Cause Indicates that port is faulted due to port re-initialization failure.
Recommended
Action
Whenever this error is observed persistently, power cycle the specified blade. If the problem
persists, replace the blade.
Severity ERROR
CDR-1017
Message <timestamp>, [CDR-1017], <sequence-number>,, ERROR, <system-name>, Blade in Slot
<slot number> faulted due to unavailable ports in internal Trunk.
Probable Cause Indicates that blade is faulted due to unavailable ports in internal trunk.
Recommended
Action
Whenever this error is observed persistently, power cycle the specified blade. If the problem
persists, replace the blade.
Severity ERROR
CDR-1018
Message <timestamp>, [CDR-1018], <sequence-number>,, ERROR, <system-name>, Blade in Slot
<slot number> faulted due to Link reset threshold value exceeded.
Probable Cause Indicates that blade is faulted due to Link reset threshold exceeded.
Recommended
Action
Whenever this error is observed persistently, power cycle the specified blade. If the problem
persists, replace the blade.
Severity ERROR
CDR-1019
Message <timestamp>, [CDR-1019], <sequence-number>,, WARNING, <system-name>, S<slot
number>,C<chip index>: HW ASIC Chip TXQ FID parity error threshold reached type =
0x<chip error type>.
Probable Cause Indicates an internal error in the ASIC hardware that may degrade data traffic.