Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 125
53-1002448-01
Chapter
18
CNM System Messages
CNM-1001
Message <timestamp>, [CNM-1001], <sequence-number>,, ERROR, <system-name>, Failed to
allocate memory: (<function name>).
Probable Cause Indicates that the specified function failed to allocate memory.
Recommended
Action
Check memory usage on the switch using the memShow command. Restart or power cycle the
switch.
Severity ERROR
CNM-1002
Message <timestamp>, [CNM-1002], <sequence-number>,, ERROR, <system-name>, Failed to
initialize <module> rc = <error>.
Probable Cause Indicates that an initialization of a module within the CNM has failed.
Recommended
Action
Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS
Command Reference Manual for more information on this command.
Severity ERROR
CNM-1003
Message <timestamp>, [CNM-1003], <sequence-number>,, WARNING, <system-name>, Crypto
device configuration between local switch (<local domain id>) and peer (<peer
domain id>) is out of sync. New encryption session is not allowed.
Probable Cause Indicates that the Encryption Engine (EE) nodes in the cluster encryption group have different
configurations.
Recommended
Action
Synchronize the configuration in the cluster group using the cryptodevicecfg command. Refer to the
Fabric OS Command Reference Manual for more information on this command.
Severity WARNING