Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

146 Fabric OS Message Reference
53-1002448-01
CONF-1021
19
CONF-1021
Message <timestamp>, [CONF-1021], <sequence-number>,, INFO, <system-name>, configUpload
not permitted <AD Number if AD is configured on the system>.
Probable Cause Indicates a configUpload operation is not permitted. There are many possible causes.
Recommended
Action
Execute the errShow command to view the error log. Correct the error and execute the
configUpload command again.
Severity INFO
CONF-1022
Message <timestamp>, [CONF-1022], <sequence-number>,, WARNING, <system-name>, Downloading
configuration without disabling the switch was unsuccessful.
Probable Cause Indicates an attempt to download the configuration without disabling the switch was unsuccessful
because there are one or more parameters that require the switch to be disabled.
Recommended
Action
Disable the switch using the switchDisable command and download the configuration.
Severity WARNING
CONF-1023
Message <timestamp>, [CONF-1023], <sequence-number>,, INFO, <system-name>, configDownload
failed <Message>.
Probable Cause Indicates a configDownload operation has failed.
Recommended
Action
Execute the errShow command to view the error log. Correct the error and execute the
configDownload command again.
Severity INFO
CONF-1024
Message <timestamp>, [CONF-1024], <sequence-number>,, INFO, <system-name>, configUpload
failed <Message>.
Probable Cause Indicates a configUpload operation has failed.
Recommended
Action
Execute the errShow command to view the error log. Correct the error and execute the
configUpload command again.
Severity INFO