Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

160 Fabric OS Message Reference
53-1002448-01
CVLC-1031
21
CVLC-1031
Message <timestamp>, [CVLC-1031], <sequence-number>,, WARNING, <system-name>, Primary LUN
is restored from mirror LUN. LUN in read-only mode.
Container: <Target container name>, Initiator: <Initiator physical WWN>, LUN ID:
<LUN ID>.
Probable Cause Indicates a rekeyed primary LUN may have been restored from mirror LUN without synchronizing.
Recommended
Action
1. Create a new primary LUN.
2. Add it to its container with -newLUN option.
3. Using host based migration application, copy data from old to new primary LUN.
Severity WARNING
CVLC-1032
Message <timestamp>, [CVLC-1032], <sequence-number>,, INFO, <system-name>, Secondary
metadata for LUN has been restored.
Container: <Target container name>, Initiator: <Initiator physical WWN>, LUN ID:
<LUN ID>.
Probable Cause Indicates the host I/Os to secondary metadata region.
Recommended
Action
No action is required.
Severity INFO
CVLC-1033
Message <timestamp>, [CVLC-1033], <sequence-number>,, INFO, <system-name>, Rebalance
completed for EE: <EE name>
Device login in progress.
Probable Cause Indicates a rebalance operation was performed.
Recommended
Action
No action is required.
Severity INFO
CVLC-1034
Message <timestamp>, [CVLC-1034], <sequence-number>,, INFO, <system-name>, Rekey failed
on Container: <Target container name>, Initiator: <Initiator physical WWN>, LUN
ID: <LUN ID> because <Failure reason>.
Probable Cause Indicates the First time encryption, Key expired or Manual re-key operation failed.