Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

164 Fabric OS Message Reference
53-1002448-01
CVLM-1004
22
CVLM-1004
Message <timestamp>, [CVLM-1004], <sequence-number>,, WARNING, <system-name>, Crypto
device configuration between local switch (<local switch WWN>) and peer (<peer
switch WWN>) is out of sync. New encryption session is not allowed.
Probable Cause Indicates that EE nodes in the cluster encryption group have different configurations.
Recommended
Action
Synchronize the configuration in the cluster group using the cryptocfg
--commit command. Refer to
the Fabric OS Command Reference Manual for more information on this command.
Severity WARNING
CVLM-1005
Message <timestamp>, [CVLM-1005], <sequence-number>,, INFO, <system-name>, Crypto service
is <status> on the switch.
Probable Cause Indicates that Crypto service is enabled or disabled on the switch.
Recommended
Action
No action is required.
Severity INFO
CVLM-1006
Message <timestamp>, [CVLM-1006], <sequence-number>,, WARNING, <system-name>, Crypto
device <device WWN> in target container <container name> is not in AD0.
Probable Cause Indicates that the crypto device in the crypto target container is not in AD0.
Recommended
Action
Use the ad command to move the crypto device into AD0. Refer to the Fabric OS Command
Reference Manual for more information on this command.
Severity WARNING
CVLM-1007
Message <timestamp>, [CVLM-1007], <sequence-number>,, WARNING, <system-name>, Redirect
zone update failure. Status is <status>.
Probable Cause Indicates that the redirect zone update has failed.
Recommended
Action
Issue the cryptocfg
--commit command again. Refer to the Fabric OS Command Reference Manual
for more information on this command.
Severity WARNING