Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 183
53-1002448-01
EM-1006
25
EM-1006
Message <timestamp>, [EM-1006], <sequence-number>, FFDC, CRITICAL, <system-name>, <FRU
Id> has faulted. Sensors below minimum limits.
Probable Cause Indicates that the sensors show the voltage is below minimum limits. The switch or specified blade
is being shut down for environmental reasons; the voltage is too low.
Recommended
Action
If this problem occurs on a blade, it usually indicates a hardware problem on the blade; replace the
blade.
If this problem occurs on a switch, it usually indicates a hardware problem on the main board;
replace the switch.
Severity CRITICAL
EM-1007
Message <timestamp>, [EM-1007], <sequence-number>, FFDC, CRITICAL, <system-name>, <FRU
Id> is being reset. Sensors has exceeded max limits.
Probable Cause Indicates that the voltage on a switch has exceeded environmental limits. A reset is sent to the
faulty slot or the switch (for nonbladed switches).
Recommended
Action
There is most likely a voltage hardware problem on the blade or motherboard of the switch.
For the Brocade DCX, 24000, and 48000, replace the blade field-replaceable unit (FRU).
For the Brocade 3900 replace the motherboard FRU.
For the Brocade 200E, 300, 3016, 3250, 3850, 4012, 4016, 4018, 4020, 4024, 4100, 4900,
5000, 6510, 7500, AP7600, and Brocade Encryption Switch, replace the switch.
Severity CRITICAL
EM-1008
Message <timestamp>, [EM-1008], <sequence-number>, FFDC, CRITICAL, <system-name>, Unit in
<Slot number or Switch> with ID <FRU Id> is faulted, it is incompatible with the
<type of incompatibility> configuration, check FOS firmware version as a possible
cause.
Probable Cause Indicates that a blade inserted in the specified slot or the switch (for nonbladed switches) is not
compatible with the platform configuration (includes the firmware version) or the switch
configuration. The blade is faulted.
Recommended
Action
If the blade is incompatible, upgrade the firmware or replace the blade and make sure the
replacement blade is compatible with your control processor (CP) type and firmware.
If the incompatibility is with the logical switch configuration, change the configuration using the
lscfg command to be consistent with the blade type, or remove the blade.
Severity CRITICAL