Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

184 Fabric OS Message Reference
53-1002448-01
EM-1009
25
EM-1009
Message <timestamp>, [EM-1009], <sequence-number>, FFDC, CRITICAL, <system-name>, <FRU
Id> powered down unexpectedly.
Probable Cause Indicates that the environmental monitor (EM) received an unexpected power-down notification
from the specified field-replaceable unit (FRU). This may indicate a hardware malfunction in the
FRU.
Recommended
Action
Reseat the FRU. If the problem persists, replace the FRU.
Severity CRITICAL
EM-1010
Message <timestamp>, [EM-1010], <sequence-number>, FFDC, CRITICAL, <system-name>,
Received unexpected power down for <FRU Id> But <FRU Id> still has power.
Probable Cause Indicates that the environmental monitor (EM) received an unexpected power-down notification
from the specified field-replaceable unit (FRU). However, the specified FRU still appears to be
powered up after four seconds.
Recommended
Action
Reseat the blade. If the problem persists, replace the blade.
Severity CRITICAL
EM-1011
Message <timestamp>, [EM-1011], <sequence-number>, FFDC, CRITICAL, <system-name>,
Received unexpected power down for <FRU Id>, but cannot determine if it has power.
Probable Cause Indicates that the environmental monitor (EM) received an unexpected power-down notification
from the specified field-replaceable unit (FRU) ; however, after four seconds it cannot be
determined if it has powered down or not.
Recommended
Action
Reseat the blade. If the problem persists, replace the blade.
Severity CRITICAL
EM-1012
Message <timestamp>, [EM-1012], <sequence-number>, FFDC, CRITICAL, <system-name>, <FRU
Id> failed <state> state transition, unit faulted.
Probable Cause Indicates that the specified switch blade or nonbladed switch failed to transition from one state to
another. It is faulted. The specific failed target state is displayed in the message. There are serious
internal Fabric OS configuration or hardware problems on the switch.