Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 185
53-1002448-01
EM-1013
25
Recommended
Action
Reseat the specified field-replaceable unit (FRU).
If the problem persists, restart or power cycle the switch.
Execute the diagPost command to make sure that Power-On Self-Test (POST) is enabled; then
power cycle the blade using the slotPowerOff and slotPowerOn commands or have the blade's
ejector switch cycled to run POST and verify that the blade does not have any hardware problems.
If the problem still persists, replace the FRU.
Severity CRITICAL
EM-1013
Message <timestamp>, [EM-1013], <sequence-number>,, ERROR, <system-name>, Failed to
update FRU information for <FRU Id>
.
Probable Cause Indicates that the environmental monitor (EM) was unable to update the time alive or the original
equipment manufacturer (OEM) data in the memory of a field-replaceable unit (FRU).
Recommended
Action
If you had executed the fruInfoSet command, execute the command again; otherwise, the update is
automatically attempted again. If it continues to fail, reseat the FRU.
If the problem persists, replace the FRU.
Severity ERROR
EM-1014
Message <timestamp>, [EM-1014], <sequence-number>,, ERROR, <system-name>, Unable to read
sensor on <FRU Id> (<Return code>).
Probable Cause Indicates that the environmental monitor (EM) was unable to access the sensors on the specified
field-replaceable unit (FRU).
Recommended
Action
Reseat the FRU. If the problem persists, replace the FRU.
Severity ERROR
EM-1015
Message <timestamp>, [EM-1015], <sequence-number>,, WARNING, <system-name>, Warm recovery
failed (<Return code>).
Probable Cause Indicates that a problem was discovered when performing consistency checks during a warm boot.
Recommended
Action
Monitor the switch. If the problem persists, restart or power cycle the switch.
Severity WARNING