Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

186 Fabric OS Message Reference
53-1002448-01
EM-1016
25
EM-1016
Message <timestamp>, [EM-1016], <sequence-number>,, WARNING, <system-name>, Cold recovery
failed (<Return code>).
Probable Cause Indicates that a problem was discovered when performing consistency checks during a cold boot.
Recommended
Action
Monitor the switch.
If the problem persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.
Severity WARNING
EM-1018
Message <timestamp>, [EM-1018], <sequence-number>, FFDC, CRITICAL, <system-name>, CP
blade in slot <slot number> failed to retrieve current chassis type (<return
code>/<error code>/0x<unit number>).
Probable Cause Indicates that there was a failure to read the chassis type from the system.
Recommended
Action
Verify that the control processor (CP) blade is operational and is properly seated in its slot.
Severity CRITICAL
EM-1019
Message <timestamp>, [EM-1019], <sequence-number>,, WARNING, <system-name>, Current
chassis configuration option (<Chassis config option currently in effect>) is not
compatible with standby firmware version (Pre 4.4), cannot allow HA Sync.
Probable Cause Indicates that the current chassis configuration option is not supported by the firmware on the
standby control processor (CP). This is true even if the standby CP comes up and is operational.
High availability (HA) synchronization of the CPs will not be allowed.
Recommended
Action
Change the chassis configuration option to 1 using the chassisConfig command, or upgrade the
firmware on the standby CP to the version running on the active CP.
Severity WARNING
EM-1020
Message <timestamp>, [EM-1020], <sequence-number>, FFDC, ERROR, <system-name>, Unit in
<Slot number> with ID <FRU Id> is faulted, it's an FCoE blade and the Ethernet
switch service is not enabled. Please run <fosconfig --enable ethsw>.
Probable Cause Indicates that a blade inserted in the specified slot requires the Ethernet switch service, which is
not enabled. The blade is faulted.