Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

190 Fabric OS Message Reference
53-1002448-01
EM-1042
25
Recommended
Action
No action is required.
Severity INFO
EM-1042
Message <timestamp>, [EM-1042], <sequence-number>,, WARNING, <system-name>, Important FRU
header data for <FRU Id> is not valid).
Probable Cause Indicates that the specified field-replaceable unit (FRU) has an incorrect number of sensors in its
FRU header-derived information. This could mean that the FRU header was corrupted or read
incorrectly, or corrupted in the object database, which contains information about all FRUs.
Recommended
Action
Reseat the FRU. If the problem persists, replace the FRU.
Severity WARNING
EM-1043
Message <timestamp>, [EM-1043], <sequence-number>,, WARNING, <system-name>, Can't power
<FRU Id> <state (on or off)>.
Probable Cause Indicates that the specified field-replaceable unit (FRU) cannot be powered on or off.
Recommended
Action
The specified FRU is not responding to commands and should be replaced.
Severity WARNING
EM-1044
Message <timestamp>, [EM-1044], <sequence-number>,, WARNING, <system-name>, Can't power
on <FRU Id>, its logical switch is shut down
Probable Cause Indicates that the specified field-replaceable unit (FRU) cannot be powered on because the
associated logical switch is shut down.
Recommended
Action
Execute the switchStart command on the associated logical switch.
Severity WARNING