Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 191
53-1002448-01
EM-1045
25
EM-1045
Message <timestamp>, [EM-1045], <sequence-number>,, WARNING, <system-name>, <FRU Id> is
being powered <new state>.
Probable Cause Indicates that an automatic power adjustment is being made because of the (predicted) failure of a
power supply or the insertion or removal of a port blade.
The new state value can be one of the following:
On - A port blade is being powered on because the power is available (a power supply was
inserted or a port blade was removed or powered down).
Off - A port blade has been powered down because of the (predicted) failure of the power
supply.
Down - A newly inserted port blade was not powered on because there was not enough power
available.
Recommended
Action
The Brocade 24000 requires only a single power supply for a fully populated chassis; however, you
must always operate the system with at least two power supplies for redundancy.
Severity WARNING
EM-1046
Message <timestamp>, [EM-1046], <sequence-number>,, WARNING, <system-name>, Sysctrl
reports error status for blade ID <id value> for the blade in slot <slot number>
<blade incompatibility type: platform, backplane, or switch configuration>
Probable Cause Indicates that the specified blade is incompatible.
Recommended
Action
If the blade ID listed is incorrect, the field-replaceable unit (FRU) header for the blade is corrupted
and the blade must be replaced.
If the error is due to platform, the blade ID listed is not supported for that platform (CP) type.
Remove the blade from the chassis.
If the error is due to backplane, the CP type (CP256) is not supported on that chassis (backplane
revision D2). Remove the blade from the chassis.
If the error is due to switch configuration, the blade’s logical switch configuration is not correct.
Execute the lscfg command to correct the switch or port configuration for the ports on the blade.
Severity WARNING
EM-1047
Message <timestamp>, [EM-1047], <sequence-number>,, INFO, <system-name>, CP in slot <slot
number> not faulty, CP ERROR deasserted.
Probable Cause Indicates that the control processor (CP) is no longer faulted. This message usually follows the
EM-1033 message. The new standby CP is in the process of restarting and has turned off the
CP_ERR signal.