Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

198 Fabric OS Message Reference
53-1002448-01
EM-2003
25
EM-2003
Message <timestamp>, [EM-2003], <sequence-number>,, ERROR, <system-name>, <Slot Id or
Switch for pizza boxes> has failed the POST tests. FRU is being faulted.
Probable Cause Indicates that a field-replaceable unit (FRU) has failed the Power-On Self-Test (POST). Refer to the
/tmp/post[1/2].slot#.log file for more information on the faults. To view this log file you must be
logged in at the root level. The ID will be Switch for nonbladed systems.
Recommended
Action
On bladed systems, reseat the specified FRU.
On nonbladed switches, restart or power cycle the switch.
If the problem persists, perform the following actions:
Execute the diagPost command to make sure that Power-On Self-Test (POST) is enabled; then
power cycle the blade using the slotPowerOff and slotPowerOn commands or have the blade's
ejector switch cycled to run POST and verify that the blade does not have any hardware
problems.
On bladed systems, replace the specified FRU; otherwise replace the switch.
Severity ERROR