Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

204 Fabric OS Message Reference
53-1002448-01
ESW-1004
27
ESW-1004
Message <timestamp>, [ESW-1004], <sequence-number>,, ERROR, <system-name>,Blade attach
failed during recovery, disabling slot = <slot number>.
Probable Cause Indicates that the blade has failed during failover or recovery.
Recommended
Action
On a Brocade 8000 switch, restart or power cycle the switch.
Severity ERROR
ESW-1005
Message <timestamp>, [ESW-1005], <sequence-number>,, ERROR, <system-name>,Diag attach
failed during recovery, disabling slot = <slot number>.
Probable Cause Indicates that the Diag blade attach command has failed during failover or recovery.
Recommended
Action
On a Brocade 8000 switch, restart or power cycle the switch.
Severity ERROR
ESW-1006
Message <timestamp>, [ESW-1006], <sequence-number>,, WARNING, <system-name>, HA state out
of sync: Standby CP (ver = <standby SWC version>) does not support NPIV
functionality. (active ver = <active SWC version>, NPIV devices = <'1' if NPIV
devices exist; Otherwise '0'>).
Probable Cause Indicates that the standby control processor (CP) does not support N_Port ID Virtualization (NPIV)
functionality, but the switch has some NPIV devices logged into the fabric.
Recommended
Action
Load a firmware version on standby that supports NPIV functionality, using the firmwareDOwnload
command.
Severity WARNING
ESW-1007
Message <timestamp>, [ESW-1007], <sequence-number>,, WARNING, <system-name>,Switch port
<port number> disabled due to \"<disable reason>\".
Probable Cause Indicates that the switch port is disabled due to the reason displayed in the message.