Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 213
53-1002448-01
FABR-1013
29
FABR-1013
Message <timestamp>, [FABR-1013], <sequence-number>, FFDC, CRITICAL, <system-name>, No
Memory: pid=<fabric process id> file=<source file name> line=<line number within
the source file>.
Probable Cause Indicates that there is not enough memory in the switch for the fabric module to allocate. This
message is rare and usually indicates a problem with the Fabric OS.
Recommended
Action
The system will recover by failing over to the standby CP.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity CRITICAL
FABR-1014
Message <timestamp>, [FABR-1014], <sequence-number>, , ERROR, <system-name>, Port <port
number> Disabled: Insistent Domain ID <Domain ID> could not be obtained. Principal
Assigned Domain ID = <Domain ID>
Probable Cause Indicates that the specified port received an request domain ID (RDI) accept message containing a
principal-switch-assigned domain ID that is different from the insistent domain ID (IDID). Fibre
Connectivity (FICON) mode requires an insistent domain ID. If an RDI response has a different
domain ID, then the port is disabled.
Recommended
Action
Run the configShow command to view the fabric.ididmode. A ‘0’ means the IDID mode is disabled;
a 1 means it is enabled.
Set the switch to insistent domain ID mode. This mode is set under the configure command or in
Web Tools on the Switch Admin > Configure window.
Severity ERROR
FABR-1015
Message <timestamp>, [FABR-1015], <sequence-number>,, ERROR, <system-name>, FICON
Insistent DID max retry exceeded: All E-Ports will be disabled. Switch is
isolated.
Probable Cause Indicates that the application exceeded request domain ID (RDI) requests for the insistent domain
ID. All E_Ports are disabled, isolating the specified switch from the fabric.
Recommended
Action
Verify that the insistent domain ID is unique in the fabric and then re-enable the E_Ports. Run the
fabricShow command to view the domain IDs across the fabric and the configure command to
change the insistent domain ID mode. Refer to the Fabric OS Command Reference for more
information on these commands.
Severity ERROR