Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 225
53-1002448-01
Chapter
30
FABS System Messages
FABS-1001
Message <timestamp>, [FABS-1001], <sequence-number>, FFDC, CRITICAL, <system-name>,
<Function name> <Description of memory need>
Probable Cause Indicates that the system is low on memory and cannot allocate more memory for new operations.
This is usually an internal Fabric OS problem or file corruption. Description of memory need
indicates how much memory was being requested. The value could be any whole number.
Recommended
Action
Reboot or power cycle the switch.
Severity CRITICAL
FABS-1002
Message <timestamp>, [FABS-1002], <sequence-number>,, WARNING, <system-name>, <Function
name> <Description of problem>
Probable Cause Indicates that an internal problem has been detected by the software. This is usually an internal
Fabric OS problem or file corruption.
Recommended
Action
Reboot or power cycle the switch.
If the message persists, run the firmwareDownload command to update the firmware.
Severity WARNING
FABS-1004
Message <timestamp>, [FABS-1004], <sequence-number>,, WARNING, <system-name>, <Function
name and description of problem> process <Process ID number> (<Current command
name>) <Pending signal number>.
Probable Cause Indicates that an operation has been interrupted by a signal. This is usually an internal Fabric OS
problem or file corruption.
Recommended
Action
Reboot or power cycle the switch.
Severity WARNING