Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

242 Fabric OS Message Reference
53-1002448-01
FCOE-1024
34
Recommended
Action
No action is required.
Severity WARNING
FCOE-1024
Message <timestamp>, [FCOE-1024], <sequence-number>,, WARNING, <system-name>, FDISC
received from Enode without prior FLOGI.
Probable Cause Indicates that no root Nport has logged in.
Recommended
Action
No action is required.
Severity WARNING
FCOE-1025
Message <timestamp>, [FCOE-1025], <sequence-number>,, WARNING, <system-name>, FCOE logout
received on FIP VN port.
Probable Cause Indicates that a pre-FIP logout for a device that has logged in using FIP protocol.
Recommended
Action
It is due to a CNA or target driver issue. No action is required.
Severity WARNING
FCOE-1026
Message <timestamp>, [FCOE-1026], <sequence-number>,, WARNING, <system-name>, FDISC/FLOGI
mismatch. FDISC addressed to different FCF than base FLOGI.
Probable Cause Indicates the base port has sent an FLOGI but the subsequent FDISCs that was received on the
switch does not match the original FLOGI.
Recommended
Action
It is due to a CNA or target driver issue. No action is required.
Severity WARNING
FCOE-1027
Message <timestamp>, [FCOE-1027], <sequence-number>,, ERROR, <system-name>, <msg>: <mac1>
<mac2> <mac3> <mac4> <mac5> <mac6>.
Probable Cause Indicates that an FDISC is received after an FLOGI but the associated controller cannot be found.