Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

254 Fabric OS Message Reference
53-1002448-01
FCR-1005
37
Recommended
Action
Verify that the devices were intended to be taken offline. If not, verify that the devices are
functioning properly. Verify that all small form-factor pluggables (SFPs) are seated correctly. Check
for faulty cables, deteriorated SFPs, or dirty connections. Replace the cables and SFPs if necessary.
Severity INFO
FCR-1005
Message <timestamp>, [FCR-1005], <sequence-number>,, INFO, <system-name>, FC router LSAN
zone device removed at port <port number>.
Probable Cause Indicates that a device is removed from the logical storage area network (LSAN) zone in the edge
fabric.
Recommended
Action
No action is required.
Severity INFO
FCR-1006
Message <timestamp>, [FCR-1006], <sequence-number>,, INFO, <system-name>, FC router LSAN
zone device added at port <port number>.
Probable Cause Indicates that a device is added to a logical storage area network (LSAN) zone in the edge fabric.
Recommended
Action
No action is required.
Severity INFO
FCR-1007
Message <timestamp>, [FCR-1007], <sequence-number>,, INFO, <system-name>, FC router LSAN
zone deleted at port <port number>.
Probable Cause Indicates that a logical storage area network (LSAN) zone attached to the specified port was
deleted from the edge fabric.
Recommended
Action
No action is required.
Severity INFO