Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

268 Fabric OS Message Reference
53-1002448-01
FCR-1061
37
VC_RDY mode: Virtual-channel flow control mode. This is a proprietary protocol.
R_RDY mode: Receiver-ready flow control mode. This is the Fibre Channel standard protocol, that
uses R_RDY primitive for flow control.
Severity WARNING
FCR-1061
Message <timestamp>, [FCR-1061], <sequence-number>,, INFO, <system-name>, Backbone fabric
created on port <port number>.
Probable Cause Indicates that a backbone fabric was built on the specified port.
Recommended
Action
No action is required.
Severity INFO
FCR-1062
Message <timestamp>, [FCR-1062], <sequence-number>,, INFO, <system-name>, Port <port
number> disabled, system only supports <maximum ports> EX/VEX_ports.
Probable Cause Indicates that the maximum number of supported EX_ports or VEX_ports was exceeded. To enable
the specified port, disable any other operational port then re-enable the port.
Recommended
Action
No action is required.
Severity INFO
FCR-1063
Message <timestamp>, [FCR-1063], <sequence-number>,, INFO, <system-name>, Fabric <fabric
ID> for switch with domain ID: <domain ID> mismatch with local fabric ID <local
fabric ID>.
Probable Cause Indicates that the fabric ID of the switch does not match the local switch.
Recommended
Action
Run the switchShow command to display the fabric ID. Change the fabric ID to match on both ends
by modifying either the local or remote host using the fcrConfigure command.
Severity INFO