Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 281
53-1002448-01
FICN-1007
38
FICN-1007
Message <timestamp>, [FICN-1007], <sequence-number>,, ERROR, <system-name>,
DevDiskEgr:FICON Selective Reset:Path=<VEPortNumber HostDomain HostPort
DeviceDomain> <DevicePort LPAR CUADDR DeviceAddr> State=0x<current Emulation
State> stat_array=0x<the Last 4 Status values that were received from the device>.
Probable Cause Indicates that a Selective Reset from the channel was received as normal part of path recovery or
starting sequence in an error case.
Recommended
Action
If there was a job failure associated with this event, contact your switch service provider.
Severity ERROR
FICN-1008
Message <timestamp>, [FICN-1008], <sequence-number>,, ERROR, <system-name>,
DevDiskEgr:FICON Purge Path received Path=<VEPortNumber HostDomain HostPort
DeviceDomcontactain> <DevicePort LPAR CUADDR DeviceAddr>.
Probable Cause Indicates a FICON Purge Path was received from the channel as a part of path recovery.
Recommended
Action
If there was a job failure associated with this event, contact your switch service provider.
Severity ERROR
FICN-1009
Message <timestamp>, [FICN-1009], <sequence-number>,, INFO, <system-name>,
DevIng:CmdReject Sense Data rcvd:Path=<VEPortNumber HostDomain HostPort
DeviceDomain> <DevicePort LPAR CUADDR DeviceAddr> <Current Emulation State>
LastCmds=<the Last 4 commands issued to the device> Sense Data:Bytes0-0xB=<bytes
0-3 of sense data from the device> <bytes 4-7 of sense data from the device>
<bytes 8-0x0b of sense data from the device>.
Probable Cause Indicates a Unit Check status was received from a device and a sense command was issued to
read the sense data.
Recommended
Action
If there was a job failure associated with this event, contact your switch service provider.
Severity INFO