Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

288 Fabric OS Message Reference
53-1002448-01
FICN-1030
38
FICN-1030
Message <timestamp>, [FICN-1030], <sequence-number>,, ERROR, <system-name>,
HostDiskIng:FICON Purge received:Path=<VEPortNumber HostDomain HostPort
DeviceDomain> <DevicePort LPAR CUADDR DeviceAddr>.
Probable Cause Indicates an active disk emulation device received a FICON Purge Path from the channel.
Recommended
Action
If there was an unexpected job failure or IO Error associated with this event, contact your switch
service provider.
Severity ERROR
FICN-1031
Message <timestamp>, [FICN-1031], <sequence-number>,, WARNING, <system-name>,
HostDiskIng:FICON System Reset received on Path=<VEPortNumber HostDomain HostPort
DeviceDomain><DevicePort LPAR><CUADDR>.
Probable Cause Indicates the FICON channel sent a System Reset to the disk control unit.
Recommended
Action
No action is required. The MVS system was set to IPL or performing error recovery.
Severity WARNING
FICN-1032
Message <timestamp>, [FICN-1032], <sequence-number>,, INFO, <system-name>,
HostDiskIng:XRC Read Channel Extender Capabilities detected on Path:
<VEPortNumber HostDomain HostPort DeviceDomain> <DevicePort LPAR CUADDR
DeviceAddr>.
Probable Cause Indicates that the XRC SDM was restarted to discover the capabilities of the channel extension
equipment.
Recommended
Action
No action is required. This is part of the XRC initialization.
Severity INFO
FICN-1033
Message <timestamp>, [FICN-1033], <sequence-number>,, INFO, <system-name>,
HostEgr:Logical Path Established on Path=<VEPortNumber HostDomain HostPort
DeviceDomain> <DevicePort LPAR> <CUADDR>.
Probable Cause Indicates that the peer side FICON Control Unit has accepted a logical path establishment
command sequence with the FICON channel.