Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

318 Fabric OS Message Reference
53-1002448-01
FICN-2005
38
FICN-2005
Message <timestamp>, [FICN-2005], <sequence-number>,, INFO, <system-name>, FICON VEPort
<VE port number> Feature Change verified Xrc <1 or 0 - XRC Emulation Enabled or
Disabled> TapeWrt <1 or 0 - Tape Write Emulation Enabled or Disabled> TapeRd <1 or
0 - FICON Tape Read Emulation Enabled or Disabled> TinTir <1 or 0 - FICON TIN/TIR
Emulation Enabled or Disabled> DvcAck <1 or 0 - FICON Device Level Ack Emulation
Enabled or Disabled> RdBlkId <1 or 0 - FICON Write Emulation Read Block ID
Emulation Enabled or Disabled>.
Probable Cause Indicates the configuration was changed manually.
Recommended
Action
No action is required.
Severity INFO
FICN-2006
Message <timestamp>, [FICN-2006], <sequence-number>,, WARNING, <system-name>, FICON
VEPort <VE port number> Feature Change failed Xrc <1 or 0 - XRC Emulation Enabled
or Disabled> TapeWrt <1 or 0 - Tape Write Emulation Enabled or Disabled> TapeRd <1
or 0 - FICON Tape Read Emulation Enabled or Disabled> TinTir <1 or 0 - FICON
TIN/TIR Emulation Enabled or Disabled> DvcAck <1 or 0 - FICON Device Level Ack
Emulation Enabled or Disabled> RdBlkId <1 or 0 - FICON Write Emulation Read Block
ID Emulation Enabled or Disabled>.
Probable Cause Indicates the FCIP Tunnel ID associated with the FICON tunnel must be down or disabled for a
feature change to become effective.
Recommended
Action
Disable the applicable FCIP tunnel to make the feature change effective.
Severity WARNING
FICN-2064
Message <timestamp>, [FICN-2064], <sequence-number>,, INFO, <system-name>, Ingress
Abort:Oxid=0x<the OXID of the aborted exchange>:Unknown Path on
VEPort=<VEPortNumber> from SID=0x<Source Domain><Source Port> to
DID=0x<Destination Domain><Destination Port>.
Probable Cause Indicates an abort operation has been received from a local FC interface for an exchange.
Recommended
Action
If there were associated IO errors at the same time as this event, contact your vendor's customer
support for assistance.
Severity INFO