Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

336 Fabric OS Message Reference
53-1002448-01
FSS-1004
43
If the problem persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.
Severity WARNING
FSS-1004
Message <timestamp>, [FSS-1004], <sequence-number>,, ERROR, <system-name>, Memory
shortage.
Probable Cause Indicates that the system ran out of memory.
Recommended
Action
Execute the memShow command to view memory usage in the switch.
For dual CP system, enable the HA state synchronization using the haSyncStart command. For
nonbladed systems, restart the switch using the reBoot command.
If the problem persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.
Severity ERROR
FSS-1005
Message <timestamp>, [FSS-1005], <sequence-number>,, WARNING, <system-name>, FSS read
failure.
Probable Cause Indicates that the read system call to the FSS device has failed.
Recommended
Action
If the problem persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.
Severity WARNING
FSS-1006
Message <timestamp>, [FSS-1006], <sequence-number>,, WARNING, <system-name>, No FSS
message available.
Probable Cause Indicates that data is not available on the FSS device.
Recommended
Action
If the problem persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.
Severity WARNING